400G AOC vs. DAC: Which Is Better for Short Router-to-Router Links?
For two routers in the same rack, compare the cable route, power per end, port support and replacement access before choosing a 400G DAC or AOC.

AXONODE / NETWORK DEPLOYMENT
For two routers in the same rack, the useful comparison starts with the cable route, the power at each end and how the connection will be maintained.
At a glance: which cable goes on the shortlist first?
| Cable | Put it first when | Watch out for |
|---|---|---|
| Passive DAC | The connection is short and uncomplicated, with a clean route. | “DAC” is not a complete specification; active copper needs separate consideration. Check the port, the power allowance and the required FEC settings. |
| AOC | The route is longer, the copper assembly is awkward to manage, or the installation benefits from a lighter cable. | A fixed assembly: the optical ends and fiber are permanently attached, so replacement means routing a complete spare. Check the power figure per end. |
| Separate optics and fiber | The connection must pass through optical patch panels, or separately replaceable components are a priority. | The port, FEC and trial checks in the sections below still apply. |
Imagine two routers mounted close together in a cabinet. Their 400G ports appear to be about 30 cm apart, so the short length seems straightforward. The realistic question is not how to connect two ports that are close together. Rather, the question is how to choose a cable that will work on those exact ports, on the routed path and when a spare is needed.
There are still two decisions hidden in that line: whether 0.3m is the right installed length, and whether passive copper, active optical cable or separate optics and fiber is the right connection type.
For a short, uncomplicated router-to-router connection, we would put a supported passive DAC on the initial shortlist. AOC deserves consideration when the route is longer, the copper assembly is awkward to manage, or the installation benefits from a lighter cable. That is a starting point for comparison, not a rule that applies to every rack.
This article concerns a straight-through 400GbE link between two ports. A 400G-to-4x100G breakout or a connection between separate sites is a different design problem.
Measure the route, not the gap between ports
Measure the route a cable actually travels before selecting it. The 30cm gap between two front panels is not the cable length.
There is a reason to check the cable drawing rather than measure only the free space between ports:
- NVIDIA distinguishes the bend radius along a cable from the larger radius that may be required near its connector.
- Suppliers can define assembly length differently: some measurements include the portion of the connector inserted into the equipment, while others exclude it.[1]
A catalog length is not the same thing as usable routing distance.
Arista's published portfolio, for example, lists 400G QSFP-DD passive copper cables at 1m, 2m and 2.5m, and 400G AOCs at selected lengths from 1m to 30m. These are examples from particular cable families, not universal minimum or maximum lengths.[2]
For a request specifying 0.3m, we would first ask for the port positions and intended routing. A standard assembly may be more practical than a custom one, but neither should be selected before checking bend clearance and slack storage.
Two cables, two jobs: copper first, light when the route demands it
Passive DAC — the signal stays electrical
A passive direct-attach copper cable carries the signal electrically from one connector to the other. It has no laser or transceiver inside its ends, so it does not add the active power of an AOC. Juniper describes passive DAC as a lower-cost option for very short interconnects.[3]
That makes it a reasonable first candidate for an uncomplicated, short connection where the route is simple and the devices are adjacent. It also avoids the extra power that an AOC draws at each end. This matters when many ports are grouped into one rack and thermal planning is more constrained.
Still, “DAC” is not a complete specification. Active copper is a separate category: it contains signal conditioning and changes the power, reach and interface requirements. NVIDIA's linear active copper documentation illustrates that distinction. An active electrical cable should not inherit the assumptions made for a passive DAC.[4]
There is also no extra bandwidth prize for moving to optical cabling inside a data hall: a supported passive DAC and an AOC both deliver 400GbE across the listed short-reach range, and a link should be specified by the criteria in the trailing checks.
AOC — light inside the cable, copper at the plug
AOC converts the electrical signal into light inside the cable ends, while presenting a QSFP-DD connector to each port. The active components are integrated into the cable, so extra transceivers and separate cables are unnecessary.[3]
That can be useful even over a short distance, when the racks are farther apart or a lighter cable is more manageable. It also avoids having to purchase and route a separate transceiver and fiber patch panel. The cable can therefore be run as a conventional cable and terminated at both ends, without disturbing the optics at the endpoints.
The maintenance trade-off is more substantial: An AOC is a fixed assembly: the optical ends and fiber are permanently attached. That means a failed AOC cannot be treated as a spare module or as a pair of transceivers. It has to be taken to the patch panel and replaced as a whole.[4]
Consider how a replacement would be installed and whether a complete spare could be run through the same route. If the cable is hidden behind a cabinet and the route is long or awkward, an AOC should not be assumed to be a direct replacement for a DAC.
For a single, accessible router pair, the cost of the assembled cable matters less than for a deployment of many links. If the cabinets are crowded and the cable routing is unclear, AOC is a plausible alternative for one or more straightforward in-rack links.
Power: read the figure per end, not the jacket
A thin cable can still draw more power than its jacket suggests. In some situations, a published maximum power figure of 1.5W for a passive DAC and a 12W maximum power figure for an AOC have been observed, although these are maximum figures and consume more per port. The relevant comparison is therefore the published power figure per cable end.
Cisco's 400G QSFP-DD datasheet gives a useful, product-specific example:[5]
| Cable family | Illustrative power per end | Illustrative power at two ends |
|---|---|---|
| QDD-400-CUxM passive copper | 1.5W | 3W |
| QDD-400-AOCxM active optical | 12W | 24W |
The table's caveats, in short:
- These are published maximum figures for those Cisco families, not measured operating consumption, Axonode specifications or a universal DAC-versus-AOC ratio.
- The two-end totals are arithmetic sums; they do not include the routers' own power consumption.
- The table does not establish compatibility with an Arista platform.
It does show why “passive means exactly zero watts” and “AOC is always cooler” are poor purchasing shortcuts. Ask for the actual proposed part number's rating, and check whether it is quoted per end or per complete assembly.[5]
For a remote cabinet, we would evaluate endpoint power together with cable routing and the host's cooling limits. A cable choice should not depend on jacket thickness alone. The related article on 400G optics in outdoor cabinets covers the broader thermal questions.
Same speed on the label? Check the port, the profile and FEC
Before comparing prices, identify the exact port at each end. Arista offers 400G connectivity in both QSFP-DD and OSFP form factors, and its EOS documentation shows that port profiles can change the number of interfaces and their operating speeds. “Two Arista routers with 400G ports” leaves too much unspecified.[2][6]
A useful request includes:
- both hardware models
- the selected ports
- software releases
- connector form factors
- the intended native 400GbE mode
For mixed-vendor equipment, check both endpoints rather than treating acceptance at one end as proof for the other.
We would also verify the cable's supported electrical interface, port power allowance and required forward error correction settings. Host recognition is only one part of qualification; the link must establish and carry traffic in the intended configuration.
A short cable is not a reason to disable FEC. Cisco documents the host-side RS(544,514) requirement for its PAM4-based 400G QSFP-DD optics. The applicable setting for a particular cable and platform should come from its support documentation, not an assumption that one meter is too short for errors.[7]
Trial it on the real ports before you buy a batch
Before buying a batch, we would test one proposed assembly on the intended pair of ports. Record the part number, cable length, endpoint software and configuration. Route it as it will be installed, including the cable manager and normal cabinet-door clearance.
Then check link establishment and traffic forwarding, and inspect the available interface, CRC and FEC statistics. A nonzero corrected-FEC counter alone is not proof that a cable is defective: FEC exists to correct errors. Equally, correction activity should not be ignored simply because the link stays up.[7]
For acceptance:
- Compare error rates and trends with the platform's guidance.
- Investigate uncorrectable errors, packet loss and link flaps.
- In a controlled test or maintenance window, verify that the connection recovers after a restart.
- Where available, record the cable-end temperature readings alongside the operating conditions.
There is a physical check too: can the door close without pressing on the cable, can adjacent modules be removed, and could the same route accept a replacement without improvisation?
For a straightforward in-rack link, our first comparison would usually favor a supported passive DAC on cost and endpoint power. We would choose AOC when its reach or routing advantages justify the additional active electronics. If patch panels and separately replaceable components are priorities, we would examine discrete optics and fiber instead.
The quote to ask for
The most useful quote is therefore a proposed assembly for a known pair of ports and a measured route—not simply the cheapest item labeled “400G.”
For an Axonode cable review, send:
- two device models, selected port types and the routed cable length
- software versions
- a photo of the proposed route when available
We can then review suitable DAC or AOC candidates and identify what still needs validation before an order.
Discuss the connection with Axonode · jenny@axonodesolution.com